Location:Home > Products > Dehumidifier
9000 combined dehumidifier
Description
Product Parameters sheet
Model Parameters |
TZH-Y-F-09RD |
TZH-Y-F-09DR |
TZH-Y-F-09RR |
TZH-Y-F-09RRR |
|
Energy efficiency rating |
A |
B |
C |
D |
|
Processed airflow rate m3/h |
9000 |
||||
The excess pressure of air-out Pa |
≥2000 |
||||
Power of main fan kW |
11 |
||||
Refrigerating capacity kw |
≥145 |
||||
Compressor(HP) |
50 |
60 |
50 |
50 |
|
Regeneration air flow rate m3/h |
1800 |
||||
Post heating mode |
subcooler |
electric heating |
subcooler |
subcooler |
|
heating mode in winter |
electric heating |
Heat pump of main system |
|||
Electric heating power kW |
45 |
65 |
45 |
0 |
|
wheel regenerative way |
electric heating |
heat pump |
heat pump |
heat pump |
|
power of regeneration system kW |
45 |
6 |
6 |
6 |
|
air inlet conditions |
-10~45℃/ RH60%~95% |
||||
air outlet conditions |
In winter: temperature≥25℃±3℃ RH≤45%;In spring and Autumn: temperature≤25℃±3℃ RH≤45%;In Summer: temperature≤25℃±3 ℃ RH≤45% |
||||
air outlet |
3, 250mm in diameter, with a switch valve and connector. (it can be customized according to user’s requirements) |
||||
electric cabinet |
PLC control. Electric leakage protection + phase fault protection + over and under voltage protection, overload protection and electrical shunt protection, and is provided with a self-diagnostics system. Dust proof and moisture proof. |
||||
control and display of temperature and humidity |
4 stage automatic unloading refrigeration + control of wheel regeneration temperature + cooler (or post heating) + winter heating. With outlet and inlet temperature and humidity display, refrigeration temperature display. |
||||
Fault display |
System power failure / error phase / high and lower voltage failure / overload display |
||||
Pressure display and protection |
Refrigerant high and low pressure display and protection. Voltage over-voltage and under-voltage protection. |
||||
electric current display |
Each group of motors and electric heating current display. |
||||
Air inlet filter |
Stainless steel frame, aluminum alloy material multi-layer structure of filtering net, accuracy is sub-middle effect, removable, 10 thousand times cleaning. |
||||
Communication model(optional) |
Wired (or wireless) remote monitoring and messages warning |
||||
The maximum operating power kW |
64 |
104 |
64 |
64 |
|
Installed power kW |
158 |
119 |
104 |
70 |
|
Chassis structure |
The unitary frame structure. Equipped with hanging holes, the main structure of the strength and stiffness can meet the requirement of hoisting. |
||||
equipment weight kg |
3700 |
||||
overall dimension |
3600*2050*2600 |
||||
The energy consumption comparison of various forms of dehumidifier
|
TZH-Y-F-09DD |
TZH-Y-F-09RD |
TZH-Y-F-09DR |
TZH-Y-F-09RR |
TZH-Y-F-09RRR |
Energy efficiency rating |
Traditional model |
A |
B |
C |
D |
Installed power kW |
158 |
158 |
119 |
104 |
70 |
The maximum operating power kW |
104 |
64 |
104 |
64 |
58 |
Power distribution capacity kw |
125 |
75 |
125 |
75 |
70 |
Annual average operating power kW |
69.6 |
48.8 |
46.6 |
32.2 |
29.1 |
Annual power consumption kwH |
238800 |
167160 |
159996 |
112580 |
99215 |
Energy consumption ratio |
100% |
70% |
67% |
46.3% |
41.8% |
Remarks:
1.The above data were gave according to the actual operation 332 days in 2012
2.Energy consumption data were measured in Shanghai area
3.It can be customized according to customer’s requirements. Specific configuration will be subject to technical specification.